ABB Electromagnetic flow meter FEP311/FEP315/FEP321/FEP325/FET321/FET325

ABB  Electromagnetic flow meter FEP311/FEP315/FEP321/FEP325/FET321/FET325

Model No.︰FEP300 series

Brand Name︰ABB

Country of Origin︰-

Unit Price︰-

Minimum Order︰5 pc

Inquire Now

Product Description

ProcessMaster Electromagnetic flowmeter

                 FEP311.                                                FEP315                              FEP315
(without explosion protection)                         (Zone 2 / Division 2)          (Zone 1 / Division 1)

Measured error Default: 0.4 % of measured value, 0.2 % of measured value
Nominal diameter range DN 3 ... 2000 (1/10 “ ... 80 ")
Process connection6) Flange in accordance with DIN 2501 / EN 1092-1, ASME B16.5 / B16.47, JIS, AS2129
Nominal pressure PN 10 … 100, ASME CL 150, 300, 600, 900, 1500, 2500
Liner Hard rubber (DN 15 ... 2000), soft rubber (DN 50 ... 2000), PTFE (DN 10 ... 600),
PFA (DN 3 ... 200), ETFE (DN 25 ... 600), Linatex (DN 50 ... 600)
Conductivity > 5 μS/cm (20 μS/cm for demineralized water)
Electrodes Stainless steel, Hastelloy B, Hastelloy C, platinum-iridium, tantalum, titanium, tungsten carbide
Process connection material Steel, stainless steel
IP rating IP 65, IP 67
Measuring medium temperature -25 ... 180 °C (-13 ... 356 °F)
Power supply 100 ... 230 V AC (-15 / +10%), 24 V AC (-30 / +10%), 24 V DC (-30 / +30%)
current output 4 ... 20 mA, active or passive
Pulse output Can be configured locally as active or passive using software
Switch output / switch input Optoelectronic coupler, programmable function
Display Graphical display, configurable
Housing Integral mount design: choice of single-compartment housing or dual-compartment housing.
Communication HART protocol (standard), PROFIBUS PA, FOUNDATION Fieldbus (option)
Explosion protection approvals • ATEX / IECEx zone 1, 2, 21, 22
• FM / cFM Cl 1 Div 1 (≤ DN 300), Cl 1 Div 2
• NEPSI zone 1, 2
• GOST zone 1, 2
Pressure Equipment Directive 97/23/EC Conformity assessment in accordance with category III, fluid group 1
CRN (Canadian Reg.Number) On request

1) Single-compartment housing.
2) Dual-compartment housing.
3) Design level "B" sensor.
4) Design level "B" sensor, all versions made from stainless steel.
5) Design level "C" sensor, DN 25 … 600.

Sensors

FEP321.                                                             FEP325.                                   FEP325

(without explosion protection)                 (Zone 2 / Division 2)                   (Zone 1 / Division 1)

Transmitters:

FET321.                                                             FET325.                                   FET325

(without explosion protection)                 (Zone 2 / Division 2)                   (Zone 1 / Division 1)

Sensor
Measured error Default: 0.4 % of measured value, 0.2 % of measured value
Nominal diameter range DN 3 ... 2000 (1/10 “ ... 80 “)
Process connection5) Flange in accordance with DIN 2501 / EN 1092-1, ASME B16.5 / B16.47, JIS 10K
Nominal pressure PN 10 … 100, ASME CL 150, 300, 600, 900, 1500, 2500
Liner Hard rubber (DN 15 ... 2000), soft rubber (DN 50 ... 2000), PTFE (DN 10 ... 600),
PFA (DN 3 ... 200), ETFE (DN 25 ... 600), Linatex (DN 50 ... 600)
Conductivity > 5 μS/cm (20 μS/cm for demineralized water)
Electrodes Stainless steel, Hastelloy B, Hastelloy C, platinum-iridium, tantalum, titanium, tungsten
carbide
Process connection material Steel, stainless steel
IP rating IP 65, IP 67, IP 68, (NEMA 4X)
Fluid temperature -25 ... 180 °C (-13 ... 356 °F)
Transmitters
Power supply 100 ... 230 V AC (-15 / +10 %), 24 V AC (-30 / +10 %), 24 V DC (-30 / +30 %)
current output 4 ... 20 mA, active or passive
Pulse output Can be configured locally as active or passive using software
Switch output / switch input Optoelectronic coupler, programmable function
Display Graphical display, configurable
Housing Field mount housing: choice of single-compartment housing or dual-compartment housing
Communication HART protocol (standard), PROFIBUS PA, FOUNDATION Fieldbus (option)
Approvals
Explosion protection approvals • ATEX / IECEx zone 1, 2, 21, 22
• FM / cFM Cl 1 Div 1 (≤ DN 300), Cl 1 Div 2
• NEPSI zone 1, 2
• GOST zone 1, 2
Pressure Equipment Directive 97/23/EC Conformity assessment in accordance with category III, fluid group 1
CRN (Canadian Reg.Number) On request
1) Design level "B" sensor.
2) Design level "C" sensor, DN 25 … 600.
3) Single-compartment housing.
4) Dual-compartment housing

Payment Terms︰ T/T